Crosslee G443CHELTENHAM Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Non Crosslee G443CHELTENHAM. Crosslee G474CHELTENHAM User Manual [en] Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 24
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
81139
Issue 3
52<$/&+(/7(1+$0
USERS INSTRUCTIONS
THIS CAT I
2H APPLIANCE IS FOR USE
ON NATURAL GAS G20 AT A SUPPLY
PRESSURE OF 20 mbar GB and IE
HAND THESE INSTRUCTIONS TO THE USER
Vue de la page 0
1 2 3 4 5 6 ... 23 24

Résumé du contenu

Page 1 - 52<$/&+(/7(1+$0

81139Issue 352<$/&+(/7(1+$0USERS INSTRUCTIONSTHIS CAT I2H APPLIANCE IS FOR USEON NATURAL GAS G20 AT A SUPPLYPRESSURE OF 20 mbar GB and IEHAND

Page 2

INSTALLATION REGULATIONS AND REQUIREMENTSIn the interests of both the Law and of Safety, this appliance must only be installed by a competent person i

Page 3

Page 4Clearance to side(timber surrounds etc.)Minimum clearancerequired to anycombustible material tothe side of the appliancemust be 150mm.Clearance

Page 4

Page 5

Page 5

INSTALLATION USING A 5" DIAMETER METAL FLUE BOXPage 6Important: The Flue restrictor plate must be removed see Fig 10.When the metal flue box is

Page 6

INSTALLATION OF THE APPLIANCECheck that the chimney conforms to the required specifications as previously stated. Examine the condition andcarry out a

Page 7

Page 7a (ii)If the spacer frame is to be used, attach the frame to the rear of the appliance using either the screws and captivenuts removed from the

Page 8

Page 8

Page 9

Page 9

Page 10

Page 10

Page 11

Page 11

Page 12

DESCRIPTION The Royal Cheltenham glass fronted high efficiency live fuel effect inset gas fire has been developed from thesuccessful Royal Cozyfires L

Page 13

Page 12

Page 14

CHECKING OPERATION OF FIREPurge the air from the appliance by rotating the control to the ignition position, push the control to allow the air inthe p

Page 15

Complete the registration section at the end of this booklet. Advise that any component part of this appliance beguaranteed against defective workmans

Page 16

Page 15

Page 17

SHORT PARTS LISTFor spares contact the manufacturer at the address overleaf.DESCRIPTION CROSSLEE No GC NoPiezo Igniter 40245 397 686Control Knob 4

Page 18

TECHNICAL DATAHeats Input Rates: High Setting 5.42 kW 18,500 Btu/h (Gross)Low Setting 2.34 kW 8,000 Btu/hThis fire will run for 5.4 hours on on

Page 19

DISMANTLING THE FIRE BED FOR CLEANING (see fig.3, 4 & 5)Allow the appliance to cool for 1 hour before handling any components. Remove the controls

Page 20

COAL LAYING INSTRUCTIONSLay the four front coals diagonally with the stepped corner sitting on the simulated coal front and the small cornernotch at t

Page 21

Note: Should any ‘coals’ or the coal bed become damaged, lost or broken, only the correct replacements must beobtained and fitted before the applianc

Page 22

REGISTRATION RECORDPurchaser’s Name __________________________________________________and Address _____________________________________________

Page 23

81140Issue 352<$/&+(/7(1+$0INSTALLATION AND SERVICINGINSTRUCTIONSTHIS CAT I2H APPLIANCE IS FOR USEON NATURAL GAS G20 AT A SUPPLYPRESSURE OF 20

Page 24

DESCRIPTIONThe Royal Cheltenham glass fronted high efficiency live fuel effect inset gas fire has been developed from thesuccessful Royal Cozyfires.Th

Commentaires sur ces manuels

Pas de commentaire